INSTALLATION CHECK LIST
REFER TO INSTALLATION INSTRUCTIONS
GAS SUPPLY
______ Adequate pipe size
______ Correct supply pressure (during furnace operation)
______ Manifold pressure
______ No gas leaks
______ L.P. Kit Number (if applicable)
ELECTRICAL
______ 115 V.A.C. supply (Single Circuit)
______ Polarity observed
______ Furnace properly grounded
______ Adequate wire size
FURNACE INSTALLATION
______ Adequate clearance to combustibles
______ Adequate clearance for service (at front)
DUCT STATIC PRESSURE
______ in. w.c. on heating speed
______ in. w.c. on cooling speed
______ Air temperature rise
CONDENSATE LINE
______ Trap filled with water
______ Vented
______ Sloped toward drain
______ Condensate drain line hoses connected
and clamped
______ Freeze protection (if necessary)
VENTING DIRECT VENT
______ in. diameter intake pipe
______ in. diameter exhaust pipe
______ ft. of pipe intake air
______ no. of elbows intake air
______ ft. of pipe exhaust pipe
______ no. of elbows exhaust pipe
______ Exhaust Vent Temperature
TERMINATIONS DIRECT VENT
VERTICAL
______ Intake 12" min. above roof/snow level
______ Correct relationship exhaust to intake
HORIZONTAL/VERTICAL CONCENTRIC ((-)XGY-E03A)
______ Intake 12" min. above roof/snow level
______ Intake “Y” rotated above center
______ Exhaust sloped toward furnace
HORIZONTAL STANDARD ((-)XGY-D02, -D03) US
((-)XGY-D02A, (-)XGY-D03A) CANADA
______ Correct relationship exhaust to intake
______ 12" min. above grade/snow level
HORIZONTAL ALTERNATE
((-)XGY-D02, -D03 OR -D04) US
((-)XGY-D02A, -D03A, -D04A) CANADA
______ Correct relationship exhaust to intake
______ Above anticipated snow level
VENTING NON-DIRECT VENT
______ in. diameter exhaust pipe
______ ft. of pipe exhaust
______ no. of elbows
TERMINATION NON-DIRECT VENT
VERTICAL
______ 12" min. above roof/snow level
HORIZONTAL STANDARD
______ 12" min. above grade/snow level
HORIZONTAL ALTERNATE
______ Above anticipated snow level
_____________________________ Model Number
_____________________________ Serial Number
_____________________________ Date of Installation
2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rheem RGRK-12ERAJS Series and is the answer not in the manual?

Rheem RGRK-12ERAJS Series Specifications

General IconGeneral
BrandRheem
ModelRGRK-12ERAJS Series
CategoryFurnace
LanguageEnglish

Related product manuals