ABOUT YOUR WATER HEATER
10
BLEEDING THE SOLAR COLLECTORS
It is necessary to purge air from the collector circuit:
When the water heater is to be turned on and the solar collectors and solar hot and solar cold pipes
have been drained.
After maintenance has been conducted on the pipe work and air has entered the system.
If the circulator appears not to be circulating water around the system.
Warning: Bleeding the solar collectors should be conducted in the morning, within three hours of
sunrise, when the water temperature inside the solar collectors is lower.
To purge air from the collector circuit:
Ensure the water heater is full of water and all of the hot
taps are turned off.
Using a flat blade screwdriver, open the bleed valve (if it is
not already open) fitted adjacent to the solar hot water
(from collector) inlet of the solar storage tank (see
diagram).
The mains pressure will force water to flow from the tank
and through the pipe work, expelling air from the collector
circuit through the bleed valve. This is evidenced by
spurting of water from the drain line connected to the
bleed valve.
Warning: Exercise care to avoid any splashing of
water, as water discharged from the solar collectors may
be of a very high temperature.
Close the bleed valve when water runs freely from the
drain line.
TO TURN OFF THE WATER HEATER
If you plan to be away from home for a few nights, we suggest you leave the water heater switched on.
If it is necessary to turn off the water heater:
Switch off the electrical supply at the isolating switch to the solar storage tank.
Switch off the electrical supply at the power outlet to the solar control unit (refer to note below).
Close the cold water isolation valve at the inlet to the water heater.
Note: If there is a risk of freezing conditions, the electrical supply to the solar control unit should not be
switched off unless the solar collectors are drained, otherwise damage could result (refer to “Freeze
Protection on page 8).

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rheem Solar Loline Water Heater and is the answer not in the manual?

Rheem Solar Loline Water Heater Specifications

General IconGeneral
BrandRheem
ModelSolar Loline Water Heater
CategoryWater Heater
LanguageEnglish

Related product manuals