EasyManuals Logo
Home>Rinnai>Water Heater>CONTINUUM 2424WC

Rinnai CONTINUUM 2424WC User Manual

Rinnai CONTINUUM 2424WC
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #33 background imageLoading...
Page #33 background image
Model 2424WC 800-621-941933
INSTALLER’S INSTALLATION INSTRUCTIONS
Lighting the Unit
WARNING: If you do not follow these instructions exactly, a fire or
explosion may result causing property damage, personal injury or loss
of life.
1) This water heater does not have a pilot. It is equipped with a direct ignition
device which automatically lights the burner. DO NOT TRY TO LIGHT THE
BURNER BY HAND.
2) Before operating the Continuum 2424WC smell all around the unit for gas. Be
sure to smell near the ground as leaking gas may settle there.
3) Turn the manual gas control valve on.
STOP!! READ THE SAFETY ISSUES ON PAGES 8 & 9
4) Turn on any hot water tap. The Continuum 2424WC should light and begin
heating your water.
If the Continuum 2424WCfails to light
1) DO NOT ATTEMPT TO LIGHT BY HAND.
2) Turn off the electrical power to the unit.
3) Turn off the manual gas control.
4) Wait 5 minutes, if you smell gas, go to a neighbor's house and call the gas
company or the fire department. If you do not smell gas, go to the next step.
5) Turn the manual gas control valve on.
6) Turn the electrical power to the unit on.
7) Turn on any hot water tap.
8) If the unit still fails to light, turn off the electricity and gas to the unit and call
Rinnai 1-800-621-9419.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rinnai CONTINUUM 2424WC and is the answer not in the manual?

Rinnai CONTINUUM 2424WC Specifications

General IconGeneral
BrandRinnai
ModelCONTINUUM 2424WC
CategoryWater Heater
LanguageEnglish

Related product manuals