TLSZR/L-GD2
10 10000302608 Ver 00 July 2012
Connections
Status/Diagnostic LED Indicator
For Learn Process LED error codes, see page 12.
8-Pin Micro (M12)
Color Function Pin
8-Pin Cordset
889D-F8AB-*
or cable version
White Aux 1
Brown 24V DC+ 2
Green Lock 3
Yellow Safety B+ 4
Grey Safety A 5
Pink Safety B 6
Blue Gnd / 0V 7
Red Safety A+ 8
* Replace symbol with 2 (2 m), 5 (5 m), or 10 (10 m) for standard cable lengths.
Operating
Status/Diagnostic LED State Meaning
Solid Green Door/Guard closed and locked, safety outputs active.
Solid Red Door/Guard not locked, safety outputs off.
Blinking Red Unit failure. See Troubleshooting, below.
Blinking Green Door/Guard closed and locked, no input signal.
Troubleshooting
Status/Diagnostic LED State Status Troubleshooting
Off Not powered N/A
Solid Green OSSD on N/A
Solid Red OSSD not active N/A
Blinking Green Power up test
or
Safety inputs not present
Check 24V DC or OSSD inputs (yellow and red wire)
Blinking Red 1 Hz Flash: Recoverable fault
4 Hz Flash: Non-recoverable fault
Recoverable fault: Check OSSD. Outputs are not shorted to GND,
24V DC, or each other. Cycle power.
Non-recoverable fault: Cycle power.