TLSZR/L-GD2
4 10000302608 Ver 00 July 2012
Technical Specifications
Safety Ratings
Standards IEC 60947-5-3, IEC 60947-5-1, IEC 61508, EN ISO 13849-1, IEC 62061, ISO 14119
Safety Classification: Guard door sensing PLe per ISO 13849-1, SIL 3 per IEC 61508 and IEC 62061, PDF-M per IEC 60947-5-3
Functional Safety Data: Guard door sensing PFHD: 1.69 x 10
-9
Dual channel interlock may be suitable for use in application up to PLe (according
to ISO 13849-1) and for use up to SIL3 systems (according to IEC 62061)
depending application characteristics. Mission time/PTI: 20 years or 1 x 10
6
cycles.
Certifications CE Marked for all applicable EU directives, cULus (UL 508), and TÜV.
Operating Characteristics
TLSZR-GD2 Power to release
TLSZL-GD2 Power to lock
Assured Locking Distance [mm (in.)] Maximum target distance: 13 (0.51)
Maximum clearance between actuator base and switch in the door-closed
position: 5 mm (See “Clearance in Closed Position [mm (in)]” on page 8)
Torque for M5 Mounting 1.4 Nm (12.39 lb-in.)
Torque for Cover Mounting 1.2 Nm (10.62 lb-in.)
Locking Force Fmax Plastic pins: 1950 N (488 lb) Steel bolts: 2600 N (585 lb)
Locking Force Fzh (with EN/ISO 14119) Plastic pins: 1500 N (337 lb) Steel bolts: 2000 N (450 lb)
Maximum Output Current (all outputs) 200 mA
Current Consumption - solenoid not energized (no load
supply current)
50 mA
Current Consumption - solenoid energized (no load supply
current)
120 mA (260 mA inrush)
Solenoid Duty Cycle 100%
Off-State Current < 0.5 mA DC
Maximum Number of Switches, connected in series Unlimited. See “Unit Response Time” on page 14.
Operating Voltage Ue 24V DC +10% / -15%
Frequency of Operating Cycle 1 Hz
Actuation Speed, Max. 160 mm (6.29 in.) per second
Actuation Speed, Min. 100 mm (3.94 in.) per minute
Response Time (Off) 75 ms first switch, 25 ms additional for each switch
Utilization Category (IEC 60947-5-2) DC-13 24V 200 mA
Impulse Withstand Voltage Uimp 250V
Pollution Degree 3
Protection Class 2
Mechanical Life 1 x 10
6
cycles
Outputs (Guard door closed and locked)
Outputs Description Status
Safety 2 x PNP, 0.2 A max. ON (+24V DC)
Auxiliary 1 x PNP, 0.2 A max. OFF (0V DC)
Environmental
Operating Temperature [C (F)] -10°…+60° C (+14°…+140° F)
Operating Humidity 5%…95% relative