EasyManuals Logo

Roland EM-50 User Manual

Roland EM-50
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #49 background imageLoading...
Page #49 background image
Please
bear
in
mind
that
you
will
only
hear
the
differ-
ence
when
the
Reverb
effect
is
on
("P9
ft),
ChrType
(Chorus
Type)
(Default:
CH3)
This
parameter
allows
you
to
specify
the
sound
of
the
Chorus
effect.
We
could
try
to
describe
them,
but
you
will
get
a
better
idea
by
select-
ing
one
after
the
other.
Flanger
(FLN)
or
Feedback
Chorus
(FbC)
can
be
interesting
for
guitar
Tones.
Again,
there
are
two
echo
effects:
Short
Delay
(SdY)
and
Short
Delay
with
Feedback
(SdF).
They
are,
how-
ever,
much
shorter
than
those
available
for
the
Reverb
effect
processor.
Note:
Please
bear
in
mind
that
you
will
onlv
hear
the
dif-
ference
when
the
Chorus
effect
is
on
(0S
$8
),
Scale
C-Scale
B
(Scale
Tune)
(463——64,
Default:
O
for
all
notes)
These
parameters
allow
you
to
stray
away
from
the
usual
semitone-
interval
scale
(used
in
western
music)
by
changing
the
pitch
of
the
notes
so
as
to
accommodate
other
musical
cultures
or
tuning
methods
(oriental,
baroque
music,
etc.).
As
you
will
notice,
you
can
change
the
pitch
of
every
note
of
one
octave
(C,
C#,
D,
Eb,
E...).
The
settings
you
make
here
apply
to
all
notes
of
the
same
name
(i.c.
to
every
C,
every
C£,
ctc.).
Most
of
the
time,
you
will
probably
select
the
value
“+50”
or
"—50"
as
they
correspond
exactly
to
half
a
semitone
up
or
down
(guarter
tone).
Other
settings
are
possible,
though.
Note:
These
Scale
settings
only
apply
to
the
Upper]
and
Upper2
parts.
Song
P1-Song
P16
(On,
MtN,
MtA,
Default:
On)
We
already
discussed
these
parameters
while
talking
about
the
Recorder
(see
page
37).
Select
“On”
for
a
Song
part
you
want
to
hear,
and
“Mtn”
or
“MtA”
for
Song
parts
you
wish
to
mute.
The
difference
between
“MtN”
and
“MtA'
is
of
little
importance
for
Song
parts
that
are
not
linked
to
a
Realtime
part,
so
choose
whichever
you
like.
The
Song
parts
that
have
no
link
with
the
Realtime
parts
are:
Song
P1,
2, 5,
7-9,
and
11-16.
Part
Switches
(U/S)
The
following
parameters
are
called
"part
switches"
because
they
allow
you
to
choose
whether
the
settings
contained
in
a
Recorder
song
may
affect
the
settings
currently
in
effect
(SNG)
or
whether
the
User
Pro-
gram
or
current
panel
settings
(USP)
should
take
precedence.
More
specifically,
you
can
choose
to
filter
the
follow-
ing
Song
settings:
U/S
MTun—(Default:
SNG)
This
is
the
Master
Tune
filter.
The
Master
Tune
setting
is
usually
absent
in
Standard
MIDI
Files.
There
is,
however,
another
important
aspect
that
makes
this
parameter
very
EM-50/30
meaningful
indeed.
Suppose
you
programmed
a
User
Program
with
a
Master
Tune
setting
of
442Hz
because
the
violin
player
you
wish
to
accompany
prefers
that
tuning.
Pressing
[|-«]
or
simply
starting
play
back
of
the
Recorder
would
cause
the
Master
Tune
setting
to
revert
to
440Hz
(because
that
is
the
default
setting),
so
that
you
suddenly
sound
hopelessly
flat
with
respect
to
the
violin.
If,
however,
you
select
“USP”,
your
EM-50/30
remains
tuned
at
442Hz
provided
you
changed
the
Master
Tune
setting
by
hand
or
selected
a
User
Program
con-
taining
that
Master
Tune
value.
U/S
Rev
and
U/S
Chr—(Default:
SNG)
These
switch-
es
are
filters
for
the
Reverb
and
Chorus
effects.
Select
“USP”
here
if
you
do
not
like
the
effect
settings
of
the
song
you
are
playing
back.
U/S
UP1,
UP2,
LWR,
MDR—These
switches
allow
you
to
ignore
the
settings
of
the
Song
parts
linked
to
the
Realtime
parts.
In
fact,
these
are
the
link
switches
between
the
Song
parts
and
the
assigned
Realtime
parts.
Selecting
“USP”
breaks
the
link
between
the
parts
in
question.
See
“Live
performance
with
song
backing
(Minus
One)”
on
page
37
for
more
informa-
tion
about
these
links.
The
most
important
parameters
that
can
be
protected
from
unwanted
modification
are:
volume
(Balance),
Pitch
Bend
Range,
Chorus,
Tone
selection,
and
Scale
Tune
(only
for
Upperl
and
Upper2).
Remember
that
breaking
the
link
is
not
enough,
as
that
only
means
that
the
corresponding
Song
part
settings
will
not
be
used.
Don't
forget
to
make
your
own
desired
settings,
or
load
a
suitable
User
Program.
Note:
Though
you
can
only
activate
or
deactivate
the
Cho-
rus
for
the
Upper1,
Upper2,
Lower
&
M.Drums
parts
on
the
EM-50/30's
front
panel,
the
tone
generator
is
capable
of
applying
Chorus
to
any
part.
If
the
Standard
MIDI
File
you
play
back
contains
such
settings,
they
will
be
faithfully
carried
out
in
SNG
mode.
Resume
This
function
allows
you
to
recall
the
default
settings
of
all
Parameter
mode
functions
(i.e.
the
ones
in
effect
when
you
switch
on
your
EM-50/30
without
selecting
a
User
Program).
Press
[ENTER]
in
response
to
the
flashing
“ENT”
message
to
recall
the
default
settings.
If,
at
that
time,
a
User
Program
is
selected,
the
dashes
appear
below
its
address
to
indicate
that
your
User
Program
has
been
edited.
49
m
Z
e
Eis
wn
IT

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Roland EM-50 and is the answer not in the manual?

Roland EM-50 Specifications

General IconGeneral
BrandRoland
ModelEM-50
CategoryElectronic Keyboard
LanguageEnglish

Related product manuals