Power supply 2 x AA batteries
Rating max 3(1) A
Output signal NO/COM/NC relay
Temperature range 5 - 35°C
Display temperature accuracy 0.1°C or 0.5°C
Control algorithm
TPI or Hysteresis: ±0.25°C, ±0.5°C,
±1.0°C or ±1.5°C
Communication Wired
Dimension [mm] 96 x 96 x 27
The RT310 thermostat requires no special maintenance. Periodically, the outer casing can be wiped clean using a dry cloth (please DO NOT use solvents,
polishes, detergents or abrasive cleaners, as these can damage the thermostat). There are no user serviceable parts within the unit; any servicing or
repairs could only be carried out by Salus Controls or their appointed agents.