EasyManuals Logo

Sanyo CL0971 User Manual

Sanyo CL0971
81 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #26 background imageLoading...
Page #26 background image
6. ELECTRICAL DATA
6-1. Electrical Characteristics
Indoor Unit KS0971
Outdoor Unit C0971
Indoor Unit Outdoor Unit Complete Unit
Fan Motor Fan Motor + Compressor
Performance at 115V Single-phase 60Hz
Rating conditions Running amp. A 0.45
Power input W
A
W
45
7.15
710
Rating conditions: Indoor air temperature: 80°F (26.7°C) D.B. / 67°F (19.4°C) W.B.
Outdoor air temperature: 95°F (35°C) D.B.
Cooling
7.6
755
Indoor Unit KS0971
Outdoor Unit CL0971
Indoor Unit Outdoor Unit Complete Unit
Fan Motor Fan Motor + Compressor
Performance at 115V Single-phase 60Hz
Rating conditions Running amp. 0.45
Power input 45
7.15
710
Cooling
7.6
755
Rating conditions: Indoor air temperature: 80°F (26.7°C) D.B. / 67°F (19.4°C) W.B.
Outdoor air temperature: 95°F (35°C) D.B.
26

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sanyo CL0971 and is the answer not in the manual?

Sanyo CL0971 Specifications

General IconGeneral
BrandSanyo
ModelCL0971
CategoryAir Conditioner
LanguageEnglish

Related product manuals