Special Remarks
How it works? Once the room temperature reaches the level that was set, the unit
repeats the cycle of turning on and off automatically.
During DRY operation, the fan speed is automatically set to LOW or
VERY LOW; the fan speed then switches back and forth between LOW
(for 20 seconds) and VERY LOW (for 10 seconds).
‘‘DRY’ operation is not possible if the indoor temperature is 15°C or less.
In the event of power failure, the unit will stop. When the power is
resumed, the unit will restart automatically after three minutes.
In cooling operation, any plastic parts may expand or shrink due to a
sudden temperature change. In this event, a clicking sound may occur.
This is normal, and the sound will soon disappear.
The remote control unit sends the setting condition to the air conditioner
regularly at three minute intervals.
Remote Contro Unit
Clicking sound is
heard from the
air conditioner
Clicking Sound
Power failure during
operation
“DRY” ( ) Operation
OI-378-15EG
15
SAP-K121GJA-oi 3/4/00 16:50pm Page 15
Все каталоги и инструкции здесь: http://splitoff.ru/tehn-doc.html

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sanyo SAP-C91GA and is the answer not in the manual?

Sanyo SAP-C91GA Specifications

General IconGeneral
BrandSanyo
ModelSAP-C91GA
CategoryAir Conditioner
LanguageEnglish

Related product manuals