6. ELECTRICAL DATA
6-1. Electrical Characteristics
Indoor Unit SAP-K77GHAX
Outdoor Unit SAP-C77GHAX
31
Rating conditions: Indoor air temperature: 27
C D.B. / 19 C W.B.
Outdoor air temperature: 35
C D.B.
Full Load conditions: Indoor air temperature: 32
C D.B. / 23 C W.B.
Outdoor air temperature: 43
C D.B.
Cooling
Rating conditions: Indoor air temperature: 20 C D.B.
Outdoor air temperature: 7
C D.B. / 6 C W.B.
Full Load conditions: Indoor air temperature: 27
C D.B.
Outdoor air temperature: 24
C D.B. / 18 C W.B.
Heating
Indoor Unit Outdoor Unit Complete Unit
Fan Motor Fan Motor Compressor
Performance at 220/230/240V Single phase 50Hz
Rating Conditions Running Amps. A 0.17 0.21 3.02 3.4
Power Input
k
W 0.022 0.048 0.700 0.770
Full Load Conditions Running Amps. A 0.17 0.21 3.47 3.85
Power Input
k
W 0.022 0.048 0.770 0.840
Indoor Unit Outdoor Unit Complete Unit
Fan Motor Fan Motor Compressor
Performance at 220/230/240V Single phase 50Hz
Rating Conditions Running Amps. A 0.17 0.21 2.72 3.1
Power Input
k
W 0.022 0.048 0.610 0.680
Full Load Conditions Running Amps. A 0.17 0.21 3.47 3.85
Power Input
k
W 0.022 0.048 0.770 0.840