EasyManuals Logo
Home>Sanyo>Air Conditioner>XHS2432

Sanyo XHS2432 User Manual

Sanyo XHS2432
106 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #17 background imageLoading...
Page #17 background image
1
2
3
4
– 17 –
SM830076
1. Specifications
1-3 Other Component Specifications
(B) Outdoor Unit
MODEL No. CH2432
Compressor Motor Magnetic Contactor FMCA - 1UL
Coil rated 240 VAC, 60 Hz
Coil resistance (at 77 °F) 580 ± 15 %
Contact rated (Main) 230 VAC, 20 A
Contact rated (Auxiliary) 230 VAC, 3 A
Power Relay HH62S
Coil rated 240 VAC, 60 Hz
Coil resistance (at 77 °F) k 17.2
Contact rated 220 VAC, 5 A
Power Transformer ATR - I65C
Rated
Primary 220 VAC, 60 Hz
Secondary 14 V, 0.4 A
Capacity 5.6 VA
Coil resistance (at 73 °F ) WHT WHT : 395.5 , BRN BRN : 2.19
Thermal cut off temperature °F266
Thermistor (Coil sensor) : TH6, 7
PBC - 41E - S4 , PBC - 41E - S26
Coil resistance k 14 °F : 23.7 , 50 °F : 9.7
23 °F : 18.8 , 68 °F : 6.5
32 °F : 15.0 , 86 °F : 4.4
41 °F : 12.1 , 104 °F : 3.1
113 °F : 2.6
Thermistor (Comp. discharge gas sensor) : TH8
PTC - 51H - S1
Coil resistance k 140 °F : 13.8 , 194 °F : 5.1
158 °F : 9.7 , 212 °F : 3.8
167 °F : 8.2 , 230 °F : 2.8
176 °F : 7.0 , 248 °F : 2.2
185 °F : 5.9 , 266 °F : 1.7
Solenoid control valve or coil
Solenoid control valve V 389100
Solenoid coil LB 59005
Thermistor (PTC) TDK – 101YV
Rated
Max. voltage 400 VAC
Max. ampere 11.5 A
Resistance (at 77 °F) 100 %
DATA SUBJECT TO CHANGE WITHOUT NOTICE
+ 30
– 20

Table of Contents

Other manuals for Sanyo XHS2432

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sanyo XHS2432 and is the answer not in the manual?

Sanyo XHS2432 Specifications

General IconGeneral
BrandSanyo
ModelXHS2432
CategoryAir Conditioner
LanguageEnglish

Related product manuals