1
2
3
4
– 7 –
SM830076
1. Specifications
1-1 Unit Specifications
MODEL No. Indoor Unit XHS2432
Outdoor Unit CH2432
POWER SOURCE 230 - 208 V / 1 Phase / 60 Hz
PERFORMANCE Cooling Heating
Capacity* BTU / h 24,000 23,400 25,000 24,300
(17°F)** 16,400 15,800
Moisture removal (High) Pints / h 8.6 8.4
Air circulation (Hi)
cu.ft. / min.
540 / 510
S.E.E.R. (H.S.P.F.)
BTU / Wh
10.0 10.2 (7.0) (7.0)
ELECTRICAL RATINGS
Voltage rating VAC 230 208 230 208
Available voltage range VAC 187 - 253 187 - 253
Running amperes A 11.2 11.6 11.7 12.3
Max. running amperes A
Power input* W 2,450 2,350 2,500 2,450
(17°F)** 2,150 2,020
Buck-up heater kW
Maximum fuse size A 30
FEATURES
Controls Microprocessor
Fan speeds Indoor / Outdoor 3 and Automatic control / 2 (Auto)
Timer ON / OFF 24-hours & Program
Air deflection Horizontal / Vertical — / Automatic
Air filter Washable, easy access, long life fiter (2,500 hr)
Operation sound Indoor dB - A 37 / 35 / 31
Hi / Me / Lo Outdoor - Hi dB - A 53
Refrigerant control Electronic Refrigerant Control Valve
REFRIGERANT PIPING
Limit of piping length ft. (m) 165 (50)
Limit of piping length at shipment ft. (m) 100 (30)
Limit of elevation difference ft. (m) Outdoor unit is higher than indoor unit: 165 (50)
between the two units Outdoor unit is lower than indoor unit: 100 (30)
Refrigerant piping Narrow pipe in. (mm) 1 / 4 (6.35)
Flare type Wide pipe in. (mm) 3 / 4 (19.05)

Table of Contents

Other manuals for Sanyo XHS2432

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sanyo XHS2432 and is the answer not in the manual?

Sanyo XHS2432 Specifications

General IconGeneral
BrandSanyo
ModelXHS2432
CategoryAir Conditioner
LanguageEnglish

Related product manuals