4.5.2 Electric connections: wires (Modular 60 12/24V DC)
The electric connectors are positioned inside the small electric box connected to the computer box. The power
supply, coming from the service batteries, needs to be connected to the terminals – and + . The connection
to the boat panel needs to be performed downstream the voltmeter and the ammeter of the boat panelboard.
The connecting terminal must be suitable to support the plant electric load (approx. 250 Watt). A 32 Ampere
automatic circuit breaker for 12V DC systems must be installed on the power supply , while a 16 Ampere for
24VDC systems.
The general wires connection scheme (between the external devices and the main electric box) is the following:
Electric cables and switches selection table.
The connection general diagram is the following:
Clamp connect to cable section
- negative battery see table
+ positive battery see table
- pump 1 min 10 mm2
12 pump 1 min 10 mm2
- pump 2 min 10 mm2
13 pump 2 min 10 mm2
- electrovalve (on the AC filter) 2,5 mm2
10 electrovalve (on the AC filter) 2,5 mm2
+ pressure switch (on the watermaker) 2,5 mm2
5 pressure switch (on the watermaker) 2,5 mm2