13.4 Reset procedure
If the watermaker get air (or if some other problem occurs), the automatic hydraulic valve may stop in a central
position. This means that pressures on both sides of the valve are the same and the unit is effectively stalled.
In this case the system has to be manually restarted.
An evidence of this effect is confirmed by a working pressure going up suddenly. After approx. 20 sec. the
computer recognizes the problem, turn off the pumps, and the red led start flashing.
This event, besides being very unusual, does not damage the system, but it is necessary to reset the valve
with the following simple procedure:
1. Turn off the system
2. Open the reset valve (lever in horizontal
position).
3. Open the depressurization valve at 45°.
4. Screw the positioner know clockwise until it can
be moved no further. Normally 10 turns at least
are needed.
5. Unscrew the positioner knob up to the original
position, until when it is blocked back.

Table of Contents

Other manuals for Schenker MODULAR 150

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Schenker MODULAR 150 and is the answer not in the manual?

Schenker MODULAR 150 Specifications

General IconGeneral
BrandSchenker
ModelMODULAR 150
CategoryWater Filtration Systems
LanguageEnglish

Related product manuals