• Lubricate the moving parts regularly.
• Do not allow lubricants to get onto switches, V-
belts, drive pulleys and drill stroke arms.
Maintenance
Setting the laser, g. 23 + 24
a crosshair in the centre of the drill. If the laser line
does not meet in the centre of the drill, the laser must
the drill. Loosen the locknutsIt is possible to ad-
Set the laser lines such that they cross in the middle
of the drill tip.
Adjusting the spindle retaining spring, Fig. 25
It may be necessary for the spindle retaining spring to
spindle return too quickly or too slowly.
1. To provide more space, lower the table.
2. Work on the left side of the drill.
3.
keeping it in place.
4.
5. Leaving the screwdriver in the notch, loosen the
WARNING! Spring is under
tension!
6. Using the screwdriver, carefully turn the spring cap
7. Lower the spindle to the lowest position and hold
moves up and down as desired, retighten the
8. If it is too loose, repeat steps 3-5. If it is too tight,
repeat in reverse order.
9.
NOTE: Do not over-tighten and do not restrict the
movement of the spindle!
Service information
With this product, it is necessary to note that the fol-
wear, or that the following parts are required as con-
sumables.
Wearing parts*:Carbon brushes; V-belts, drill
* may not be included in the scope of supply!
• Kinks where the connection cable has been im-
properly fastened or routed.
• Places where the connection cables have been cut
due to being driven over.
• Insulation damage due to being ripped out of the
wall outlet.
• Cracks due to the insulation ageing.
Such damaged electrical connection cables must not
be used and are life-threatening due to the insula-
tion damage.
Check the electrical connection cables for damage
regularly. Ensure that the connection cables are dis-
connected from electrical power when checking for
damage.
Electrical connection cables must comply with the
applicable VDE and DIN provisions. Only use con-
nection cables with designation H05VV-F.
The printing of the type designation on the connec-
tion cable is mandatory.
AC motor
• The mains voltage must be 230 V~
• Extension cables up to 25 m long must have a
cross-section of 1.5 square millimetres.
Connections and repair work on the electrical equip-
ment may only be carried out by electricians.
Please provide the following information in the event
of any enquiries:
• Type of current for the motor
• Machine data - type plate
• Motor data - type plate
11. Cleaning and maintenance
Pull out the mains plug before carrying out any
adjustments, maintenance or repair work.
m Have tasks that are not described in this op-
erating manual, carried out by a specialist work-
shop. Use only original parts. Let the device
cool down before all maintenance and cleaning
tasks. There is a risk of burns!
Before using the device each time, check the device
for obvious defects such as worn or damaged parts,
correct seating of screws or other parts. Replace
damaged parts.
Cleaning
Do not use cleaning agents or solvents. Chemical
substances could damage the plastic parts of the
device. Never clean the device under running water.
• Clean the device thoroughly after each use.
• Clean the ventilation holes and the surface of the
device with a soft brush or cloth.
• Remove chips, dust and dirt with a vacuum clean-
er if necessary.