12. Transport
For transport, the splitting knife A must be completely
moved down. Slightly tilt the log splitter with handle B
on the splitting column until the machine is inclined on
the wheels and can be moved. (Fig 11)
13. Storage
Store the device and its accessories in a dark, dry
and frost-proof place that is inaccessible to children.
The optimum storage temperature is between 5 and
Cover the electrical tool in order to protect it from
dust and moisture.
Store the operating manual with the electrical tool.
14. Maintenance
Attention!
Pull out the power plug before carrying out any main-
tenance work on the equipment.
When must the oil be changed?
First oil change after 50 operating hours, then every
500 operating hours.
Oil change (Fig. 12)
• Completely retract the splitting column.
• Put a container with a volume of at least 6 litres
under the splitter.
• Release the oil dipstick 6.
• Open the oil drain plug 12a under the oil tank so the
• Afterwards, close the oil drain plug 12a again.
• Remove the ventilation cap, pour in 4 litres of fresh
hydraulic oil using a clean funnel.
• Screw the oil dipstick in again.
Dispose of the used oil in a correct manner at a
public collection facility. It is prohibited to drop
old oil on the ground or to mix it with waste.
We recommend oil from the HLP 32 range.
Splitting spar
Before use, the spar of the splitter must be slightly
hours. Slightly apply grease of oil spray. The spar
may never run dry.
Hydraulic system
The hydraulic unit is a closed system with oil tank, oil
pump and control valve.
The system is complete when the machine is deliv-
ered, and may not be changed or manipulated.
This may have the following causes:
• Passage points, where connection cables are
passed through windows or doors.
• Kinks where the connection cable has been im-
properly fastened or routed.
• Places where the connection cables have been cut
due to being driven over.
• Insulation damage due to being ripped out of the
wall outlet.
• Cracks due to the insulation ageing.
Such damaged electrical connection cables must not
be used and are life-threatening due to the insula-
tion damage.
Check the electrical connection cables for damage
regularly. Make sure that the connection cable does
not hang on the power network during the inspection.
Electrical connection cables must comply with the
applicable VDE and DIN provisions. Only use con-
nection cables with the marking „H07RN“.
The printing of the type designation on the connec-
tion cable is mandatory.
For single-phase AC motors, we recommend a fuse
rating of 16A (C) or 16A (K) for machines with a high
starting current (starting from 3000 watts)!
Three-phase motor 400 V / 50 Hz
Mains voltage 400 V / 50 Hz
Mains voltage and extension cables must be 5-lead
(3P + N + SL (3/N/PE).
Extension cables must have a minimum cross-section
of 1.5 mm².
Mains fuse protection is 16 A maximum.
When connecting to the mains or relocating the ma-
chine, check the direction of rotation (swap polarity in
the wall socket if necessary).
Turn pole inverter in the machine socket.
11. Cleaning
Attention!
Pull out the power plug before carrying out any clean-
ing work on the equipment.
We recommend that you clean the equipment imme-
diately after you use it.
Clean the equipment regularly with a damp cloth and
some soft soap. Do not use cleaning agents or sol-
vents; these may be aggressive to the plastic parts in
the equipment. Ensure that no water can get into the
interior of the equipment.