LC-24LE150M
6 – 1
CHAPTER 6. ADJUSTMENT
[1] ADJUSTMENT
[1]
ADJUSTMENT PROCEDURE
1.
Entering
and
cancel the adjustment process mode
1) While holding down the
INPUT
and Volume DOWN keys at the same time, plug in the AC cord to turn on the power. (“K” standing for
inspec-
tion process mode is
displayed
on the upper left position of the
screen.)
2) Press the Channel DOWN and Volume DOWN keys at the same time. (The
adjustment
process mode screen
appears.)
3) To cancel it, turn off the power using the Power switch or remote
control.
2.
Remote controller
key
operation
and
description of display in adjustment process mode.
1. key
operation
Remote controller key
Main
unit key
F
unc
tion
CH ( /
)
CH ( /
)
Changing
selected line
(UP/DOWN)
VOL (+ /
–)
/+(LOV
–)
Changing
selected line setting
(+1/-1)
Cursor ( /
)
——————
egapagninruT
(PREVIOUS/NEXT)
Cursor ( /
)
——————
Changing
a selected line setting
(+10/-10)
INPUT button on
remote
controller
INPUT
button
elggot(gnihctiwsecruostupnI
switching)
(TV Æ INPUT1 Æ INPUT2 Æ INPUT3
)
ENTER —————— ——————
* Input mode is switched
automatically
when relevant
adjustment
is started so far as the
necessary
input signal is
available.
3.
Software
upgradin
g.
1) Plug off the LCD
TV.
2) Insert the USB device to the USB terminal at the LCD
TV.
(Make sure that the latest software is installed in the USB
device).
3) Hold the LCD TV power key and plug on the LCD
TV.
4) LCD TV is on and detecting the U SB
device.
5) A few seconds later, LED light (orange) will blink indicating the software
upgrading.
7) T V w i l l a u t o m a t i c a l l y r e s t a r t w h e n s oftware is successfully installed
8) LCD TV is running with the latest software.
LCD TV
ADJUSTMENT ITEM
1. EDID DATA
INPUT
No need to input
EDID
2. SIGNAL
ADJUSTMENT
A. PICTURE
ADJUSTMENT
Confirmation of signal from generator (setting to spec
level)
p-pV7.0langisetisopmoCLAP
+
0.02Vp-p (pedestal to white
level)
15K Component signal (50Hz) Y level 0.7Vp-p
+
0.02Vp-p (pedestal to white
level)
Pb, Pr level 0.7Vp-p : 0.7Vp-p
+
0.02Vp-p
33K Component signal Ylevel 0.7Vp-p
+
0.02Vp-p (pedestal to white
level)
+
Pb, Pr level 0.7Vp-p
0.7Vp-p
–
0.02Vp-Com