4
R-209FK
R-209FW
OPERATION
DESCRIPTION OF OPERATING SEQUENCE
POWER OUTPUT REDUCTION
If the oven is set for more than 20 minutes at 80, 90 or 100% power level, after the first 20 minutes the power level will
automatically adjust itself to 70% power to avoid overcooking.
ITEM DESCRIPTION
Power Requirements 120 Volts
60 Hertz
Single phase, 3 wire grounded
Power Consumption 1250W / Approx. 10.6 Amperes
Power Output 800 W nominal of RF microwave energy (IEC Test procedure)
Operating frequency 2450 MHz
Case Dimensions Width 18-1/8"
Height 11-3/8"
Depth 14-5/8"
Cooking Cavity Dimensions Width 12-3/8"
(0.8 Cubic feet) Height 8-3/8"
Depth 13"
Control Complement Touch Control System
Clock (1:00 - 12:59)
Timer (0 - 99 minutes 99 seconds)
Microwave Power for Variable Cooking
Repetition Rate;
P-HI ................................... Full power throughout the cooking time
P-90 .................................................... approx. 90% of FULL Power
P-80 .................................................... approx. 80% of FULL Power
P-70 .................................................... approx. 70% of FULL Power
P-60 .................................................... approx. 60% of FULL Power
P-50 .................................................... approx. 50% of FULL Power
P-40 .................................................... approx. 40% of FULL Power
P-30 .................................................... approx. 30% of FULL Power
P-20 .................................................... approx. 20% of FULL Power
P-10 .................................................... approx. 10% of FULL Power
P-0 ...................................... No power throughout the cooking time
POPCORN pad, MINUTE PLUS pad
Instant Start pads, EXPRESS DEFROST pad
Number selection pads, TIMER/CLOCK pad
POWER LEVEL pad
STOP/CLEAR pad, START pad
Oven Cavity Light Yes
Safety Standard UL Listed.
FCC Authorized
DHHS Rules, CFR, Title 21, Chapter 1, Subchapter J
PRODUCT DESCRIPTION
SPECIFICATIONS