5
R-209FK
R-209FW
Figure O-1. Oven Schematic-Off Condition
SCHEMATIC
NOTE: CONDITION OF OVEN
1. DOOR CLOSED
2. CLOCK APPEARS ON DISPLAY
NOTE: " " indicates components with potential above 250V.
POWER
TRANSFORMER
RECTIFIER
MAGNETRON
CAPACITOR
0.86µF
C/T FUSE
120V AC
60 Hz
OVEN
LAMP
TURN-
TABLE
MOTOR
FAN
MOTOR
MONITOR
SWITCH
SECONDARY
INTERLOCK
SWITCH
TTM
OL FM
GRN
A3
COM.
N.O.
DOOR
SENSING
SWITCH
B1 B2
(RY-1)
(RY-2)
CONTROL UNIT
PRIMARY
INTERLOCK
RELAY
MAGNETRON
THERMAL CUT-OUT
A1
;;;;
;;;;
;;;;
;;
;;
;;;
;;;
;;
;;;
;;
;;;
DEF. LBS. QTY.
CHECK
ON
NOTE:
Some one-touch cooking features such as
"MINUTE PLUS" are disabled after three min-
utes when the oven is not in use. These features
are automatically enabled when the door is
opened and closed or the STOP/ CLEAR pad is
pressed.
TOUCH CONTROL PANEL