Page #17 background imageLoading...
Page #17 background image
Operating Instructions
LMS1xx Laser Measurement Sensors
Product description
8012471/ZN27/2017-06-09 © SICK AG · Germany · All rights reserved · Subject to change without notice 17
Chapter 3
3 Product description
This chapter provides information on the special features and properties of the LMS1xx.
It describes the construction and the operating principle of the device, in particular the
different operating modes.
Please read this chapter before mounting, installing and commissioning the device.
3.1 Delivery
The LMS1xx delivery includes the following components:
An overview about the available LMS1xx variants, its accessories and, device documenta-
tion is available from the web product page:
http://www.sick.com/lms1xx
The configuration software SOPAS ET, the current system prerequisites for the PC, and the
instructions for downloading the software and the device description file(s) can be found
online at:
http://www.sick.com/SOPAS_ET
Section 11.1 “Ordering information” on page 104 provides an overview of available
consumables.
3.2 Device variants
Quantity Components Comment
1 An LMS1xx laser measurement sensor Model type depends on order.
Outdoor variants:
M12-round plug-in connectors
equipped with protection caps and
plugs made of plastic
1 Type-specific notes on device with
electrical circuit diagram for getting started
Is included in the LMS1xx packaging
Tab. 5: Delivery
Type Special features Heating Enclosure rating
LMS10x Indoor variant No IP 65
LMS11x Outdoor variant Yes IP 67
1)
LMS15x Outdoor version with extended functionality Yes IP 67
1
LMS12x
LMC12x
LMS173
Indoor variant, optimized for usage in object protection
systems
No IP 65
LMS13x
LMS14x
LMS182
Outdoor variant, optimized for usage in object protection
systems
Yes IP 67
1)
LMC13x Semi-outdoor variant, optimized for usage in object
protection systems
Yes IP 67
1)
1) Under the following conditions: the cables plugged into the M12 round plug-in connections must be screwed
tight. Any electrical connections that are not being used must be fitted with protective caps or plugs that are
screwed tight (as in the delivery condition
). The M8 connection on the front is screwed tight.
Tab. 6: Device variants of the LMS1xx