Chapter 4
Technical Specifications
RUGGEDCOM RS900G
Installation Guide
22 Operating Environment
Fiber Optic SFP
Mode
Connector
Type
Cable
Type (μm)
Tx λ (nm)
m
Tx min
(dBm)
Tx max
(dBm)
Rx
Sensitivity
(dBm)
Rx
Saturation
(dBm)
Distance
(km)
m
Power
Budget
(dB)
50/125 0.5
MM LC
62.5/125
850 -9 -2.5 -20 0
0.3
11
SM LC 9/125 1310 -9.5 -3 -19 -3 10 9.5
SM LC 9/125 1310 -7 -3 -23 -3 25 16
SM LC 9/125 1550 0 5 -23 -3 70 23
m
Typical.
Section 4.6
Operating Environment
Parameter Range Comments
Ambient Operating Temperature -40 to 85 °C
(-40 to 185 °F)
Measured from a 30 cm (12 in) radius surrounding the center of the
RUGGEDCOM RS900G enclosure.
Ambient Relative Humidity 5% to 95% Non-condensing
Ambient Storage Temperature -40 to 85 °C
(-40 to 185 °F)
Operating Altitude 0 to 15240 m
(0 to 50000 ft)
Over temperature range of -40 to 85 °C (-40 to 185 °F)
Section 4.7
Mechanical Specifications
Parameter Value
Dimensions Refer to Chapter 5, Dimension Drawings
Weight 1.2 kg (2.7 lbs)
Enclosure 20 AWG Galvanized Steel