Technical Specifications
5.5Fiber Optic Ethernet Port Specifications
• All optical power numbers are listed as dBm averages.
• F51 transceivers are rated for -40 to 85 °C (-40 to 185 °F).
Connector Speed Duplex
a
Cable Type
b
Wiring
Standard
c
Maximum
Distance
d
Isolation
e
RJ45 10/100 Mbps FDX/HDX > CAT-5 TIA/EIA
T568A/B
100 m
(328 ft)
1.5 kV
RJ45 1000 Mbps FDX/HDX > CAT-5 TIA/EIA
T568A/B
100 m
(328 ft)
1.5 kV
micro-D 10/100 Mbps FDX/HDX > CAT-5 TIA/EIA
T568A/B
100 m
(328 ft)
1.5 kV
micro-D 1000 Mbps FDX/HDX > CAT-5 TIA/EIA
T568A/B
100 m
(328 ft)
1.5 kV
a
Auto-Negotiating
b
Shielded or unshielded.
c
Auto-crossover and auto-polarity.
d
Typical distance. Dependent on the number of connectors and splices.
e
RMS 1 minute.
5.5 Fiber Optic Ethernet Port Specifications
The following details the specifications for fiber Ethernet ports that can be ordered
with the RUGGEDCOM RSG2100.
10FL Ethernet Optical Specifications
Tx (dBm)Mode Connec-
tor Type
Cable
Type (µm)
Tx λ
(nm)
a
Minimum Maximum
Rx Sen-
sitivity
(dBm)
Rx Sat-
uration
(dBm)
Distance
(km)
b
Pow-
er Bud-
get (dB)
MM ST 62.5/125 850 -16 -9 -34 -11.2 2 18
MM ST 50/125 850 -19.8 -12.8 -34 -11.2 2 14.2
a
Typical.
b
Typical distance. The maximum distance is greatly dependent on factors such as cable type, the number of connectors and
number of splices. Consult a Siemens sales associates when determining maximum distances.
Fast Ethernet (10/100 Mbps) Optical Specifications
Tx (dBm)Mode Connec-
tor Type
Cable
Type (µm)
Tx λ
(nm)
a
Minimum Maximum
Rx Sen-
sitivity
(dBm)
Rx Sat-
uration
(dBm)
Distance
(km)
b
Pow-
er Bud-
get (dB)
MM ST 62.5/125 1300 -19 -14 -31 -14 2 12
MM ST 50/125 1300 -22.5 -14 -31 -14 2 8.5
MM SC 62.5/125 1300 -19 -14 -31 -14 2 12
MM SC 50/125 1300 -22.5 -14 -31 -14 2 8.5
MM MTRJ 62.5/125 1300 -19 -14 -31 -14 2 12
MM MTRJ 50/125 1300 -22.5 -14 -31 -14 2 8.5
RUGGEDCOM RSG2100
Installation Manual, 03/2020, C79000-G8976-1040-17
33