EasyManuals Logo
Home>Siemens>Switch>RUGGEDCOM RSG907R

Siemens RUGGEDCOM RSG907R User Manual

Siemens RUGGEDCOM RSG907R
54 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #24 background imageLoading...
Page #24 background image
Installing the Device
2.6.1Connecting AC or DC Power
Make sure a terminal block is installed in the unused port and that any wires
from the secondary terminal block are properly terminated
Make sure the first power source is off before connecting (or disconnecting) a
second power source
1. If connecting a secondary power source, make sure the power source currently
connected to the device is disabled (e.g. power cable is unplugged from the wall
receptacle).
2. Insert the appropriate terminal block(s) into the device and tighten both screws.
Power Source Terminal Block Type
HI 3 POS
LO 5 POS
Figure2.8 Assembling the Power Terminal Blocks
IMPORTANT
Torque all terminal connections to 0.6 N·m (5 lbf-in).
3. Connect the power cable to the device as follows:
HI AC/DC Power Supply
a. Connect the Line wire (AC) or
Positive wire (DC) to the positive/
live (+/L) terminal on the terminal
block.
b. Connect the Neutral wire (AC)
or Negative wire (DC) to the
negative/neutral (-/N) terminal on
the terminal block.
3 4 5
4
3 5
2
1
1
3 POS Terminal Block
RUGGEDCOM RSG907R
Installation Manual, 02/2021, C79000-G8976-1387-12
15

Other manuals for Siemens RUGGEDCOM RSG907R

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens RUGGEDCOM RSG907R and is the answer not in the manual?

Siemens RUGGEDCOM RSG907R Specifications

General IconGeneral
BrandSiemens
ModelRUGGEDCOM RSG907R
CategorySwitch
LanguageEnglish

Related product manuals