Technical Specifications
5
This section provides important technical specifications related to the device.
5.1 Power Supply Specifications
Note
When determining cable lengths, make sure the minimum input voltage for the
power supply is provided at the power source.
Hazardous Environments
Input VoltagePower
Supply Type
Minimum Maximum Nominal
Internal
Fuse Rating
Isolation Maximum
Power
Consumption
a
LO 11.1 VDC 55 VDC 12 VDC, 24
VDC, 48 VDC
5 A 1.5 kVDC 13.4 W
100 VDC 270 VDC 125 VDC,
250 VDC
3.15 A 5 kVDC 15.3 WHI
100 VAC 240 VAC 110 VAC,
220 VAC
3.15 A 5 kVDC 15.5 W
a
Current consumption may vary based on configuration.
Non-Hazardous Environments
Input VoltagePower
Supply Type
Minimum Maximum Nominal
Internal
Fuse Rating
Isolation Maximum
Power
Consumption
a
LO 10 VDC 60 VDC 12 VDC, 24
VDC, 48 VDC
5 A 1.5 kVDC 13.4 W
88 VDC 300 VDC 125 VDC,
250 VDC
3.15 A 5 kVDC 15.3 WHI
85 VAC 264 VAC 110 VAC,
220 VAC
3.15 A 5 kVDC 15.5 W
a
Current consumption may vary based on configuration.