Technical Specifications
5
This section provides important technical specifications related to the device.
5.1 Power Supply Specifications
Note
When determining cable lengths, make sure the minimum input voltage for the pow-
er supply is provided at the power source.
Hazardous Environments
Input VoltagePower Sup-
ply Type
Minimum Maximum Nominal
Internal
Fuse Rating
Isolation Maximum
Power Con-
sumption
a
LO 11.1 VDC 55 VDC 12 VDC, 24
VDC, 48 VDC
5 A 1.5 kVDC 13.4 W
100 VDC 270 VDC 125 VDC,
250 VDC
3.15 A 5 kVDC 15.3 WHI
100 VAC 240 VAC 110 VAC,
220 VAC
3.15 A 5 kVDC 15.5 W
a
Current consumption may vary based on configuration.
Non-Hazardous Environments
Input VoltagePower Sup-
ply Type
Minimum Maximum Nominal
Internal
Fuse Rating
Isolation Maximum
Power Con-
sumption
a
LO 10 VDC 60 VDC 12 VDC, 24
VDC, 48 VDC
5 A 1.5 kVDC 13.4 W
88 VDC 300 VDC 125 VDC,
250 VDC
3.15 A 5 kVDC 15.3 WHI
85 VAC 264 VAC 110 VAC,
220 VAC
3.15 A 5 kVDC 15.5 W
a
Current consumption may vary based on configuration.
RUGGEDCOM RSG910C
Installation Manual, 02/2020, C79000-G8976-1405-06
25