Installing the Device
2.3.2Mounting the Device to a Panel
2.3.2 Mounting the Device to a Panel
For panel installations, the RUGGEDCOM RX1510 can be equipped with panel/DIN rail
adapters pre-installed on each side of the chassis. The adapters allow the device to
be attached to a panel using screws.
To mount the device to a panel, do the following:
1. Place the device against the panel and mark the mounting holes on the panel.
1
2
1
1
Screw
2
Panel/DIN Rail Adapter
Figure2.2 Panel Mounting
2. Prepare the mounting holes
3. Align the device with the mounting holes and secure it to the panel.
2.4 Connecting the Failsafe Alarm Relay
The failsafe relay can be configured to latch based on alarm conditions. The NO
(Normally Open) contact is closed when the unit is powered and there are no ac-
tive alarms. If the device is not powered or if an active alarm is configured, the relay
opens the NO contact and closes the NC (Normally Closed) contact.
Note
Control of the failsafe relay output is configurable through RUGGEDCOM RX1510.
One common application for this relay is to signal an alarm if a power failure oc-
8
RUGGEDCOM RX1510
Installation Manual, 12/2019, C79000-G8976-1055-16

Other manuals for Siemens RUGGEDCOM RX1510

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens RUGGEDCOM RX1510 and is the answer not in the manual?

Siemens RUGGEDCOM RX1510 Specifications

General IconGeneral
BrandSiemens
ModelRUGGEDCOM RX1510
CategorySwitch
LanguageEnglish

Related product manuals