Siemens Industry, Inc.
Building Technologies Division
P/N 315-050537-33
P1
P2
P3
P4
P5
P6
IN
OUT
IN
OUT
FAULT
F1
F2
L1+
M1
L2+
M2
GND FAULT
24V 12A FAIL
24V 4A FAIL
MODULE FAIL
HNET FAIL
CAN FAIL
RESET
POWER
PSC-12
P5
1
1
19
1
1
+
+
+
_
_
_
2
2
H
N
GND
6
24
12
18
7
13
12
34
TB1
TB2
BATTERY
P9
P12
TB3
TB4
P4
OFF
O
ON
P10
HNET/CAN
*NEXT
SWITCH
*NEXT
SWITCH
TO P5 IN
TO P5 IN
TO P5 OUT
TO P5 OUT
FIBER
FROM P6 IN
FROM P6 IN
FROM P6 OUT
FROM P6 OUT
FIBER
*PREVIOUS
SWITCH
*PREVIOUS
SWITCH
RJ45
VIDEO
DO NOT USE
DO NOT USE
DIAGNOSTIC
ONLY
DIAGNOSTIC
ONLY
DO NOT USE
DO NOT USE
DO NOT USE
DO NOT USE
DO NOT USE
DO NOT USE
DO NOT USE
DO NOT USE
DO NOT USE
DO NOT USE
KEYBOARD
DO
NOT
USE
DO
NOT
USE
USB
SIDE
USB
SIDE
USB
SIDE
USB
SIDE
OPTIONAL
OPTIONAL
TIE
WRAP
TIE
WRAP
ADDITIONAL 24V
NON-POWER LIMITED
ADDITIONAL 24V
NON-POWER
LIMITED
+
_
L1+
M1
BLK
RED
BLK
RED
1
2
3
4
5
1
2
3
4
5
NCC-2F
(XNET)
NCC-2F
(HNET)
CATEGORY 5 RJ45 CABLE
LESS THAN 20 FT. IN CONDUIT
CATEGORY 5 RJ45 CABLE
LESS THAN
20 FT. IN CONDUIT
SIEMENS
BLK
RED
TO AIC, TERMINAL 4 (+)
TO AIC, TERMINAL 4 (+)
TO AIC, TERMINAL 5 (-)
TO AIC, TERMINAL 5 (-)
DO NOT USE
DO NOT USE
DO NOT USE
DO NOT USE
DO NOT USE
DO NOT USE
EARTH GROUND
EARTH GROUND
PAIR B
SUPERVISED
POWER LIMITED
OMIT FOR STYLE 4
PAIR A
SUPERVISED
POWER LIMITED
NON-POWER
LIMITED
NON-POWER
LIMITED
SUPERVISED,
NON-POWER
LIMITED
SUPERVISED,
NON-POWER
LIMITED
VNT-PS
DO NOT USE
DO NOT USE
DO NOT USE
DO NOT USE
DO NOT USE
DO NOT USE
TO AIC, TERMINAL 1 (+)
TO AIC, TERMINAL 1 (+)
TO AIC, TERMINAL 2 (-)
TO AIC, TERMINAL 2 (-)
*EOLR 120 OHMS, 1/2W, 5%
P/N 140-820350
*
*
*
*
AUDIO OUT CABLE P/N 555-150464 (GREEN)
AUDIO OUT CABLE P/N 555-150464 (GREEN)
+
_
+
_
VNT
BACK OF VNT
BACK OF VNT
DO NOT USE
DO NOT USE
DO NOT USE
DO NOT USE
DO NOT USE
DO NOT USE
*WIRING SHOWN IS
STYLE 7 (CLASS A).
CAN ALSO BE WIRED
STYLE 4 (CLASS B).
*WIRING SHOWN IS
STYLE
7 (CLASS A).
CAN ALSO
BE WIRED
STYLE
4 (CLASS B).
SUPERVISED,
NON-POWER LIMITED
SUPERVISED,
NON-POWER
LIMITED
SECURE WITH TIE WRAP
TO LANCES INSIDE
THE ENCLOSURE
SECURE WITH TIE WRAP
TO
LANCES INSIDE
THE
ENCLOSURE
NOTE:
POWER LIMITED
AND NON-POWER
LIMITED WIRING
MUST BE
SEPARATED
BY A MINIMUM
OF 1/4” SPACING.
NOTE:
POWER
LIMITED
AND
NON-POWER
LIMITED
WIRING
MUST BE
SEPARATED
BY A MINIMUM
OF
1/4” SPACING.
NOTE:
POWER LIMITED
AND NON-POWER
LIMITED WIRING
MUST BE
SEPARATED
BY A MINIMUM
OF 1/4” SPACING.
NOTE:
POWER
LIMITED
AND
NON-POWER
LIMITED
WIRING
MUST BE
SEPARATED
BY A MINIMUM
OF
1/4” SPACING.
Figure 6
Fiber Switch Connection Diagram for VNT-Building
CONNECTING TO VNT-BUILDING

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens Scalance X204-2LD Single Mode and is the answer not in the manual?

Siemens Scalance X204-2LD Single Mode Specifications

General IconGeneral
BrandSiemens
ModelScalance X204-2LD Single Mode
CategorySwitch
LanguageEnglish

Related product manuals