3 Operating
IOT2000 Setting Up
Version 2.1, 08/2017
20
Siemens AG 2017 All rights reserved
3.2.2 Change IP Address
In the default settings of the SIMATIC IOT2000’s Image, the IP address is set to
192.168.200.1. Thus, if another static IP address or a DHCP address is required,
this can be set with the iot2000setup tool
The following table displays the procedure for configuring the IP address settings.
Table 3-5
No.
Action
1.
Open a valid serial Putty connection and login as root (i.e. See topic 3.3)
2.
Type in “iot2000setup” to open the setup tool, navigate to “Networking” and press
“Enter”
3.
Go to “Configure Interfaces” and press “Enter”