Configuring with Web Based Management
4.5 "Layer 2" menu
SCALANCE SC-600 Web Based Management (WBM)
Configuration Manual, 10/2021, C79000-G8976-C475-03
231
If you select "Spanning Tree" in the "Redundancy Type" drop-down list, the following
options are then available:
• STP
Enabled Spanning Tree Protocol. Typical reconfiguration times with spanning tree are
between 20 and 30 seconds. You can configure other settings in "Layer 2 > Spanning
Tree".
• RSTP
Enabled Rapid Spanning Tree Protocol (RSTP). If a spanning tree frame is detected at
a port, this port reverts from RSTP to spanning tree. You can configure other settings
in "Layer 2 > Spanning Tree".
Note
When using
RSTP (Rapid Spanning Tree Protocol), loops involving duplication of
frames or frames being overtaken may occur briefly. If this is not acceptable in your
particular application, use the slower standard spanning tree mechanism.
Passive Listening
Enable or disable the Passive Listening function.
4.5.2 VLAN
4.5.2.1 General
VLAN configuration page
On this page you can define VLANs and specify the use of the ports. The device takes
VLAN information into account (IEEE 802.1Q/VLAN-aware mode). If the device is in the
"802.1Q VLAN Bridge" mode, you can define VLANs and specify the use of the ports.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET SCALANCE SC636-2C and is the answer not in the manual?

Siemens SIMATIC NET SCALANCE SC636-2C Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC NET SCALANCE SC636-2C
CategorySwitch
LanguageEnglish

Related product manuals