Configuring with Web Based Management
4.5 "Layer 2" menu
SCALANCE SC-600 Web Based Management (WBM)
Configuration Manual, 10/2021, C79000-G8976-C475-03
241
4.5.5.3 ST Port
When the page is called, the table displays the current status of the configuration of the
port parameters.
To configure them, click the relevant cells in the port table.
Description
Table 1 has the following columns:
• All ports
Shows that the settings are valid for all ports of table 2.
• Spanning Tree Status
In the drop-down list, select the setting for all ports. If "No Change" is selected, the
entries of the corresponding column in table 2 remain unchanged.
• Copy to Table
If you click the button, the setting is adopted for all ports of table 2.
Table 2 has the following columns:
• Port
Shows the available ports.
• Spanning Tree Status
Specify whether the port is integrated in the spanning tree or not.
Note
If you disable the "Spanning Tree Status" option for a port, this may cause the
formation of loops. The topology must be kept in mind.
• Priority
Enter the priority of the port. The priority is only evaluated when the path costs are

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET SCALANCE SC636-2C and is the answer not in the manual?

Siemens SIMATIC NET SCALANCE SC636-2C Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC NET SCALANCE SC636-2C
CategorySwitch
LanguageEnglish

Related product manuals