Requirement
The device is in operation.
The function "Reset to Factory Defaults" is enabled for the "SELECT / SET" button.
Note
Reset despite disabled "SELECT/SET" button
If you have disabled the "Restore Factory Defaults" function for the "SELECT/SET" button
in the configuration, this does not apply during the startup phase, see section "Restoring
the factory settings (Page 58)".
If the function has been disabled in the configuration, it is only disabled on completion of
the startup phase.
Procedure
To reset the device to the factory defaults during operation, follow the steps below:
1. Switch to display mode A.
Display mode A is active if the LEDS "DM1" and "DM2" are unlit.
If the "DM1" and "DM2" LEDs are lit or flashing, you will need to press the "SET/SELECT"
repeatedly until the "DM1" and "DM2" LEDs go off.
If you do not press the "SELECT/SET" button for longer than 1 minute, the device
automatically changes to display mode A.
2. Hold down the "SELECT/SET" button for 12 seconds.
After 9 seconds,the "DM1" and "DM2" LEDs start to flash for 3 seconds. At the same time,
the port LEDs go on one after the other.
After you have held down the button for 12 seconds, the device restarts and the factory
defaults are restored.
If you release the button before the 12 seconds have elapsed, the reset is canceled.
Enabling and disabling the functions of the button
In the configuration, you can enable or disable the functions of the button.
Defining the fault mask
Using the fault mask, you specify an individual "good status" for the connected ports and the
power supply. Deviations from this status are displayed as errors/faults.
You configure newly plugged-in connections in the configuration.
Description of the device
3.3 SELECT / SET button
SCALANCE XC-200
28 Operating Instructions, 12/2017, C79000-G8976-C442-03

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET SCALANCE XC-200 Series and is the answer not in the manual?

Siemens SIMATIC NET SCALANCE XC-200 Series Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC NET SCALANCE XC-200 Series
CategorySwitch
LanguageEnglish

Related product manuals