4.6 Wall mounting
Preparation
Note the position of the securing bar, see also section “Dimension drawings SCALANCE
XC-200 (Page 69)“.
When supplied, the securing bar is in the wall mounting position. You do not need to prepare
the device any further.
If the securing bar is in the rail mounting position, note the section “Changing the position of
the securing bar (Page 46)“.
Tools
To mount the device on a wall, you require the following:
2 wall plugs
2 fillister head screws
Note
Depending on the mounting surface, use suitable fittings.
Assembly
Note
The wall mounting must be capable of supporting at least four times the weight of the device.
To mount the device on a wall, follow the steps below:
1. Prepare the wall mounting with drilled holes and plugs. For the precise dimensions, refer
to the section "Dimension drawings (Page 69)".
2. Turn the upper screw in to the wall so that 10 mm remains jutting out.
3. Hang the device with the keyhole hanging mechanism on the rear on the screw.
4. Fix the device to the wall with the lower screw.
5. Connect the electrical connecting cables, refer to the section "Connecting up (Page 49)".
Mounting
4.6 Wall mounting
SCALANCE XC-200
Operating Instructions, 12/2017, C79000-G8976-C442-03 45

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET SCALANCE XC208 and is the answer not in the manual?

Siemens SIMATIC NET SCALANCE XC208 Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC NET SCALANCE XC208
CategorySwitch
LanguageEnglish

Related product manuals