Communication with the S7-300
5.2 DPV1 (X1 only as PROFIBUS DP interface)
Note
If you deselect "Startup with different target / actual configurations" in the Technology CPU
properties in STEP 7, then the Technology CPU will boot even if the stations configured on
DP-DRIVE are missing.
Connectable devices
You can connect drives to PROFIBUS DP(DRIVE), e.g.:
MICROMASTER 420/430/440 and COMBIMASTER 411
SIMODRIVE 611 universal
SIMODRIVE POSMO CD/SI/CA
MASTERDRIVES MC/VC
ET 200M with IM 153-2 (isochronous!) and SM 322 for additional cam output
ET 200S with IM 151-1 high feature
SINAMICS S120 (optional with TM15 or TM17 high feature for high-speed cams)
ADI4 (analog drive interface)
Isochronous PROFIBUS encoder "SIMODRIVE sensor isochronous"
The components configured in HW Config are displayed in the "Hardware Catalog" window
in HW Config. To show the screen, select profile "SIMATIC Technology CPU" in HW Config.
To ensure that the profile's selection list is complete, you must have installed the most recent
version of S7-Technology.
Non-connectable devices
We would not recommend operating active PROFIBUS stations (PGs, PCs, OPs, TDs, etc.)
on PROFIBUS DP(DRIVE). The DP cycle will be burdened by additional access times if you
do operate these PROFIBUS stations on DP(DRIVE). In this case, isochronous processing
of drive information cannot be guaranteed.
5.2 5.2 DPV1 (X1 only as PROFIBUS DP interface)
Acyclical access with DPV1
New automation and process engineering tasks require the range of functions performed by
the existing DP protocol to be extended. In addition to cyclical communication functions,
acyclical access to non-S7 field devices is another important requirement of our customers,
and was implemented in the standard EN 50170. In the past, acyclical access was only
possible with S7 slaves.
S7-300 CPU Data: CPU 315T-2 DP
5-4 Manual, 12/2005, A5E00427933-02

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC S7-300 CPU Data: CPU 315-T-2 DP and is the answer not in the manual?

Siemens SIMATIC S7-300 CPU Data: CPU 315-T-2 DP Specifications

General IconGeneral
Programming LanguageSTEP 7
Power Supply24 V DC
Number of DP masters1
Processable Technology objectsYes
Number of counters256
Number of timers256
S7 communicationYes
Number of connections for S7 communication, max.16
PG/OP communicationYes
Global data communicationYes
Integrated DP interfaceYes
Integrated PROFINET interfaceNo
SIMATIC Computing PlatformNo
Operating Temperature0 to 60 °C
Integrated InterfacesMPI, DP
CommunicationPROFIBUS DP
Cycle Time0.1 ms
Engineering withSTEP 7
Backup availableYes
Transmission rate, max.12 Mbit/s

Related product manuals