EasyManuals Logo
Home>SMC Networks>Network Router>EZ Switch SMCGS10P-Smart

SMC Networks EZ Switch SMCGS10P-Smart User Manual

SMC Networks EZ Switch SMCGS10P-Smart
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #39 background imageLoading...
Page #39 background image
C
HAPTER
2
| Network Planning
Application Notes
– 39 –
APPLICATION NOTES
1. Full-duplex operation only applies to point-to-point access (such as when a
switch is attached to a workstation, server, or another switch). When the
switch is connected to a hub, both devices must operate in half-duplex
mode.
2. Avoid using flow control on a port connected to a hub unless it is actually
required to solve a problem. Otherwise back pressure jamming signals may
degrade overall performance for the segment attached to the hub.
3. As a general rule the length of fiber optic cable for a single switched link
should not exceed:
1000BASE-SX: 550 m (1805 ft) for multimode fiber.
1000BASE-LX: 10 km (6.2 miles) for single-mode fiber.
1000BASE-LH: 80 km (50 miles) for single-mode fiber.
100BASE-FX: 20 km (12 miles) for single-mode fiber.
However, power budget constraints must also be considered when calculating
the maximum cable length for your specific environment.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SMC Networks EZ Switch SMCGS10P-Smart and is the answer not in the manual?

SMC Networks EZ Switch SMCGS10P-Smart Specifications

General IconGeneral
BrandSMC Networks
ModelEZ Switch SMCGS10P-Smart
CategoryNetwork Router
LanguageEnglish

Related product manuals