7
340 Nm wrench:
Maximum Target Torque =
offset * 0.64 + 340
400 Nm wrench:
Maximum Target Torque =
offset * 0.63 + 400
Offset Max Target Offset Max Target
-
1"
3
24 Nm
-
25 mm
384 Nm
-
2"
308 Nm
-
50 mm
369 Nm
-
3"
292 Nm
-
75 mm
353 Nm
-
4"
276 Nm
-
100 mm
337 Nm
Note: When using a negative offset, entering a target torque greater than maximum values above may
cause an overtorque error before reaching fastener target torque and possibly damage wrench.
Viewing Stored Torque and Angle Data
Torque data is stored in memory after each torque cycle if applied torque has reached target value.
Torque and angle data is stored in memory after each angle cycle if applied angle has reached target
value. Memory Indicator is displayed when data is stored in non-volatile memory.
1. To view stored torque and angle data, from target torque or angle screen, press and hold
ENTER button for 3 seconds.
2. Highlight SHOW DATA menu selection by pressing UP /DOWN buttons then press
ENTER button to display Show Data screen.
3. In Show Data screen, scroll through each stored data record by pressing UP /DOWN buttons.
Example: 02 = Show Data List Counter: TQ = Peak torque value
01 = Show Data List Counter: TQ = Peak torque value: ANG = Peak angle value
4. Pressing ENTER button while on Show Data screen returns to main menu.
Note: A maximum of 50 data records can be stored in memory. Memory full icon will be displayed when
full. New data will replace oldest record until memory is cleared.
Deleting Stored Torque and Angle Data
1. From target torque or angle screen, press and hold ENTER button for 3 seconds.
2. Highlight CLEAR DATA menu selection using UP /DOWN buttons then press ENTER button
to display CLEAR ALL DATA screen.
3. In CLEAR ALL DATA screen, highlight YES menu selection to delete all stored data, or NO menu
selection to exit without deleting data.
4. Press ENTER button after making selection.
00
M
100.0
FT-LB
02: 15:40:15
2019/09/26
TQ: 100.2 FT-LBS
M
EXIT
SET HEAD LENGTH
SHOW DATA
M
CLEAR DATA
OR
UP/DOWN buttons
If
clock
has
been set data
timestamp will
be displayed
(see Advanced
Configuration).
01: 15:35:05
2019/09/26
TQ: 100.3 FT-LBS
M
ANG: 84°
01:
TQ: 100.3 FT-LBS
M
ANG: 84°
EXIT
SET HEAD LENGTH
SHOW DATA
M
CLEAR DATA
02:
TQ: 100.2 FT-LBS
M
ENTER
button
held
Target Screen
ENTER
button
UP/DOWN buttons
OR