Technical Specifications - Single Phase Inverters
(Europe &APAC)
SE2200 SE3000 SE3500 SE4000
SE4000-
16A
SE5000 SE6000 Unit
Output
Rated AC power
output
2200 3000 3500 4000 4000
5000
(1)
6000 VA
Maximum AC power
output
2200 3000 3500 4000 4000 5000
1
6000 VA
AC output voltage
(nominal)
220/230/240 Vac
AC output voltage
range
184 – 264.5 Vac
AC frequency
(nominal)
50/60 ±5 Hz
Maximum
continuous output
current
12
16.5
(2)
19.5
2
22 16 27 27 A
Max. continuous
overcurrent
protection
12 16.5
2
19.5
2
22 16 27 27 A
Residual current
detector/ Residual
current step detector
300/ 30 mA
Inrush current AC
(Peak/Duration)
2.8/ 20
Aac
(rms)
/ ms
Max. output fault
current
38 A
Power factor range 1 (adjustable from -0.9 to +0.9)
Total harmonic
distortion
< 3%
Protective class Class I
Utility monitoring,
islanding protection,
country configurable
thresholds
Yes
(1)
Limited to 4600VA when the inverter is set to South Africa.
(2)
16A when the country is set to Denmark, Portugal, UK, or Poland. For other countries, contact SolarEdge.
-Three Phase System Installation Guide MAN-01-00057-4.1
102 Technical Specifications - Single Phase Inverters (Europe &APAC)