Administrating the Camera
Configuring the System — System Menu
24
You can select the format between yyyy-mm-dd
hh:mm:ss (year-month-day hour:minutes:seconds),
mm-dd-yyyy hh:mm:ss (month-day-year
hour:minutes:seconds), and dd-mm-yyyy hh:mm:ss
(day-month-year hour:minutes:seconds).
Time setting
Select how to set the day and time.
Keep current setting: Select if you do not need to set
the date and time.
Synchronize with PC: Select if you want to
synchronize the camera’s date and time with the
computer.
Manual setting: Select if you want to set the cameras
date and time manually.
Select the year, month, date, hour, minutes and
seconds from each drop-down list.
Synchronize with NTP: Select if you want to
synchronize the camera’s date and time with those of
the time server called NTP server (Network Time
Protocol).
Set the NTP server when Synchronize with NTP is
selected.
NTP server
Synchronize with the selected NTP server address.
Note
When the CLOUD service is activated, you cannot set
the time and cannot change the NTP server. If you want
to set them, deactivate the CLOUD service.
Time zone
Set the time difference from Greenwich Mean Time in
the area where the camera is installed.
Select the time zone in the area where the camera is
installed from the drop-down list.
Manual time zone
If you select Manual in Time zone, you can set a desired
time zone that is not included in the list box. The input
format is compliant with IEEE 1003.1 section 8.3
standard.
Format:
stdoffset[dst[offset][,start[/time],end[/time]]]
std: 3 to 100 character strings
offset: time difference (displayed in +
-)
dst: name of summer time
offset: offset of summer time, default time is 1 hour
start: start date and time of summer time
end: end date and time of summer time
Values in [ ] can be omitted.
For example:
In case of (UTC-06:00) Central Standard Time (USA
and Canada);
CentralStandardTime6DaylightTime1,M3.2.0,M11.1.0
The name of the time zone is CentralStandardTime and
the time difference is 6 hours. The name of the summer
time is DaylightTime, and the summer time offset from
the time difference is 1 hour, starting from the second
week on Sunday in March until the first week on Sunday
in November.
Automatically adjust clock for daylight saving
time changes
When selected, the clock is automatically adjusted
according to the daylight saving time of the selected
time zone.
Note
If the time zone selected in Time zone is different from
that set on the computer, the time is adjusted using the
time zone difference and set on the camera.
OK/Cancel
See “Buttons common to every menu” on page 22.
Installation Tab
You can perform settings related to installation.
Auto iris responding speed
Supported models: SNC-VB635/VB630/VB600/
VB600B/EB630/EB630B/EB600/EB600B
When you use a non-standard lens, adjust the speed
according to the lens you use.
Select high values to make the iris respond faster, lower
values to make the iris respond slower.
Stabilizer
Set the stabilizer function. Select the checkbox to
display steadier images when the camera is installed in
a place subject to vibration.
Notes
When the stabilizer function is set, the angle of image
taken will be smaller than usual.
The stabilizer may not respond, depending on the
amount of vibration.
Be sure to set this function during the installation.
Set the privacy masking position or the motion
detection area, before setting the stabilizer.

Table of Contents

Other manuals for Sony SNC-VB600

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sony SNC-VB600 and is the answer not in the manual?

Sony SNC-VB600 Specifications

General IconGeneral
BrandSony
ModelSNC-VB600
CategorySecurity Camera
LanguageEnglish

Related product manuals