20
Command List (6/8)
Number in ( ) is MENU display values.
Command Set Command Command Packet Comments
FOCUS MODE Auto/Manual 8x 01 04 38 pp FF pp: 02=Auto Focus, 03=Manual Focus,
10=Toggle
STOP - 8x 01 04 08 00 FF
FAR Standard
speed
8x 01 04 08 02 FF
NEAR Standard
speed
8x 01 04 08 03 FF
FAR Variable
speed
8x 01 04 08 2p FF p: 0 (Low) - 7 (High)
NEAR Variable
speed
8x 01 04 08 3p FF p: 0 (Low) - 7 (High)
DIRECT - 8x 01 04 48 0p 0p 0p 0p
FF
pppp: Refer to the section of the Focus
Ratio and Focus Distance (for reference) of
VISCA Command Setting Values
ONE PUSH
TRIGGER
- 8x 01 04 18 01 FF One Push AF Trigger
FOCUS ∞ - 8x 01 04 18 02 FF
NEAR LIMIT - 8x 01 04 28 0p 0p 0p 0p
FF
pppp: Refer to the section of the Focus
Ratio and Focus Distance (for reference) of
VISCA Command Setting Values
AF MODE Mode 8x 01 04 57 0p FF p: 0=Normal AF, 1=Interval AF, 2=Zoom
Trigger AF
Interval 8x 01 04 27 0p 0p 0q 0q
FF
pp: AF operating time 00 (no operation), 01
(1 second) - FF (255 seconds)
qq: AF staying time 00 (no suspension), 01
(1 second) - FF (255 seconds)
AF SENSITIVITY - 8x 01 04 58 0p FF p: 2=Normal, 3=Low
IR CORRECTION - 8x 01 04 11 0p FF p: 0=Standard, 1=IR Light