0478 201 8312 B - EN
16
9.1 Motor restart inhibitor
The machine can only be started via the
switch and not by plugging the electric
cable into the mains socket.
9.2 Shredder box
The garden shredder can only be switched
on with the shredder box installed and
locked in place.
Once inserted, the shredder box prevents
access to the rotating blade roller during
operation.
10.1 Electrical connection of garden
shredders
Power supply and operating voltage must
correspond (see rating plate).
The power cable must be adequately
protected by fuse in line with the
respective national electrical installation
regulations. (Ö 15.)
Only electric cables which are no lighter
than rubber sheathed cables H07 RN-F
may be used.
The minimum cross-section of the power
cable must be 3x1.5mm² for a length of
up to 25 m or 3x2.5mm² for a length of
over 25 m.
The plug connections must be splash
proof.
Unsuitable extension cables lead to a loss
of power and may result in damage to the
motor.
Extension cable plugs and connectors
must conform to the standard AS/NZS
3112.
Use a splash-proof coupling box
(protection class IPX4) when using an
extension cable.
This machine is intended for operation with
a power supply having a system
impedance of Z
max
at the transfer point
(house connection) of maximum
0.49 ohms at 50 Hz.
The user must ensure that the machine is
only operated with a power supply which
meets this requirement.
If necessary, this information can be
obtained from the local electric power
company.
10.2 Connecting the power cable
● Connect the mains cable connector to
mains plug (1).
● Attach the mains cable to the strain
relief. (Ö 10.4)
10.3 Disconnecting the power cable
● Detach the strain relief. (Ö 10.4)
In order to prevent damage to the power
cable, it must only be disconnected by
pulling at the connector. Never pull at the
cable.
10.4 Strain relief
During work, the strain relief prevents any
unintentional disconnection of the electric
cable and any resulting damage to the
mains connection on the machine.
For this reason, the electric cable must be
fed through the strain relief.
9. Safety devices
10. Operating the machine
Risk of injury!
Observe the instructions in the
"Warning – dangers caused by
electrical current" section (Ö 4.2).
Your electrician can provide further
information on mains connection.