RE 362, RE 362 PLUS, RE 462, RE 462 PLUS
English
62
Electrical Specifications
Hydraulic specifications
Specifications
RE 362 RE 362 PLUS RE 462 RE 462 PLUS
Power supply: 400 V / 3~ / 50 Hz 400 V / 3~ / 50 Hz 400 V / 3~ / 50 Hz 400 V / 3~ / 50 Hz
230 V / 3~ / 50 Hz
1)
Power output: 6.3 kW 6.5 kW 7.4 kW 7.4 kW
Fuse (characteristic "C" or "K"): 16 A 16 A / 25 A
1)
16 A 16 A
Protection class: I I I I
Type of protection: IP X5 IP X5 IP X5 IP X5
1)
Norway only
RE 362 RE 362 PLUS RE 462 RE 462 PLUS
Working pressure: 3.5
-
18 MPa
(35
-
180 bar)
3.5
-
18 MPa
(35
-
180 bar)
3.5
-
22 MPa
(35
-
220 bar)
3.5
-
22 MPa
(35
-
220 bar)
Max. permissible pressure: 25 MPa (250 bar) 25 MPa (250 bar) 25 MPa (250 bar) 25 MPa (250 bar)
Max. water feed pressure: 1 MPa (10 bar) 1 MPa (10 bar) 1 MPa (10 bar) 1 MPa (10 bar)
Max. water throughput: 1080 l/h 1080 l/h 1130 l/h 1130 l/h
Water throughput as per
EN 60335
-
2
-
79: 1000 l/h 1000 l/h 1050 l/h 1050 l/h
Max. suction lift: 2.5 m 2.5 m 2.5 m 2.5 m
Max. water feed tempera
-
ture in the pressurized water
supply: 60°C 60°C 60°C 60°C
Max. water feed tempera
-
ture in suction operation: 50 °C 50 °C 50 °C 50 °C
Max. kickback force: 51 N 51 N / 49 N
1)
54 N 54 N
Oil grade (service): SAE 80W
-
90 API GL
-
5SAE80W
-
90 API GL
-
5 SAE 80W
-
90 API GL
-
5 SAE 80W
-
90 API GL
-
5
Oil quantity: 730 ml 730 ml 730 ml 730 ml
1)
Norway only