4. BATTERY INSTALLATION
7
PARTS NEEDED
Use a battery rated 12V-30AH
(EH63/64/65), 12V-36AH (EH72-2) or
larger.
Use a proper cable and ground wire
to connect battery and key switch
and electric starter.
BATTERY CABLE
GROUND WIRE, use a flat braided wire
of 0.03 sq. in. or larger sectional area.
(SAE GAUGE
4)
LA406 LA408
CABLE
EARTH (GROUND) WIRE
25mm
KEY SWITCH CABLE
For electric starter operation, proper electric wiring arrangements are needed
before normal engine operation.
CABLE
LENGTH
CABLE
DIA.
WIRE GAUGE
AWG (BS)
BWG
SAE JIS
Less than
1.5 m
7.3 mm 1 6 AV15
1.5 m
to 2.5 m
8.5 mm 0 4 AV20
2.5 m
to 4.0 m
10.8 mm 3/0 2 AV30
CABLE
LENGTH
CABLE
DIA.
WIRE GAUGE
AWG (BS)
BWG JIS
Less than
1.5 m
1.5 mm
14 16 AV1.25
1.5 m
to 3.0 m
1.9 mm
12 14 AV2
3.0 m
to 5.0 m
2.4 mm
10 13 AV3
EH72-2usEU714910.11.166:28PMページ7