22
Overview
1 Speed control
2 Driving handle
3 Hour counter (optional)
4 Drainage hose for soiled solution (with pinched neck)
5 Emptying hose for solution tank (blue cap)
6 Pedal brush unit
7 Foot pedal for squeegee
8 Squeegee
9 Charging plug for the external battery-charging unit
(only for BMS machines)
10 Lock for battery compartment (optional)
11 Tools (brush, pad drive, etc.)
12 Brush unit
13 Squeegee holder
14 Suction unit button
15 Keyswitch
16 Cleaning solution button
17 Cleaning solution dosing control
18 Emergency stop
19 Battery indicator
20 Battery charge indicator
21 Service indicator
22 Tool ejector
23 Recovery tank
24 Dirt sieve
25 Float (overfilling protection for recovery tank)
26 Vacuum air filter
27 Solution tank
28 Dosing aid
29 Tank lid catch
30 Filling level
Preparation for operation/Operation
Batteries
Safety measures when working with batteries:
Battery connection diagram
Charging procedure for traction block batteries (machines with integrated
battery charging unit)
• Protective goggles must be worn when working on the
batteries.
• Do not subject batteries to an open flame or heat as there is a
danger of explosion from the electolytic gas present in the
cells!
• No smoking!
• Danger of chemical burns!
Caution:
The battery must always be clean and dry. Do not place any
metallic objects on the battery.
The integrated charging unit is only suitable for maintenance-free
gel traction block batteries.
Caution:
Batteries may only be installed or dismounted by customer
service personnel or specialists approved by Diversey who are
aware of all the safety regulations that apply here!
• Check that the machine has been switched off with the keyswitch.
• Plug the power supply cord into the mains socket.
The yellow indicator lights up permanently until
approx. 90% of the battery capacity has been
reached. After that, the indicator blinks until the
battery is fully charged.
When the charging process is complete, the
green indicator lights up.
• Leave the power supply cord connected to the mains until you use the
machine again. The on-board charger unit automatically monitors and
charges the batteries. The energy consumption in this mode is limited to a
few milliwatts.
If a fault occurs during the charging process as
the result of a defect in the charging unit, an
interruption of a cable or a defective battery cell,
the red indicator will light up.