EasyManuals Logo
Home>Tektronix>Test Equipment>2246

Tektronix 2246 User Manual

Tektronix 2246
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #18 background imageLoading...
Page #18 background image
|
Wand
be
PER]
Section
2—2246
Operators
PREPARATION
FOR
USE
SAFETY
This
section
telis
how
to
prepare
for
and
to
proceed
with
the
initial
start-up
of
the
TEKTRONIX
2246
Oscilloscope.
Refer
to
the
Operator's
Safety
Summary
at
the
front
of
this
manual
for
power
source,
grounding,
and
other
safety
considerations
pertaining
to
the
use
of
the
instrument.
Before
connecting
the
oscilloscope
to
a
power
source,
read
both
this
section
and
the
Safety
Summary.
CAUTION
This
instrument
may
be
damaged
if
the
wrong
line
fuse
is
installed.
LINE
FUSE
To
verify
the
proper
value
of
the
instrument's
power-
input
fuse,
perform
the
following
procedure.
1.
Press
in
the
fuse-holder
cap
and
release
it
with
a
slight
counterclockwise
rotation.
2.
Pull
the
cap
(with
the
attached
fuse
inside)
out
of
the
fuse
holder.
3.
Verify
proper
fuse
value.
4,
Install
the
proper
fuse
and
reinstall
the
fuse-holder
cap.
POWER
CORD
This
instrument
has
a
detachable
three-wire
power
cord
with
a
three-contact
plug
for
connection
to
both
the
power
source
and
protective
ground.
The
power
cord
is
secured
to
the
rear
panei
by
a
cord-set
securing
clamp.
The
pro-
tective
ground
contact
on
the
plug
connects
(through
the
power
cord
protective
grounding
conductor)
to
the
accessible
metal
parts
of
the
instrument.
For
electrical
shock
protection,
insert
this
plug
into
a
power-source
outlet
that
has
a
properly
grounded
protective-ground
contact.
Instruments
are
shipped
with
the
power-cord
option
ordered
by
the
customer
(see
Figure
2-1).
Contact
your
Tektronix
representative
or
local
Tektronix
Field
Office
for
additional
power-cord
information.
INSTRUMENT
COOLING
To
prevent
instrument
damage
from
overheated
com-
ponents,
adequate
internal
airflow
must
be
maintained.
Plug
Line
Reference
Option
Configuration
Usage
Voltage
Standards
Number
DRS ana
Gee
ee
ee
re
North
ANS?
C73.11
NEMA
5-15-P
IEC
83
American
420V/
Universal
Euro
240V/
CEE
(7)
ILIV,
VN
IEC
83
240V
BS
1363
o
Australian
RAOV/
AS
C112
TOA
u
American
ZA0V/
240V
A4
15A
Switzerland
zer
220V
Abbreviations:
ANSI
American
National
Standards
Institute
AS
Standards
Association
of
Australia
BS
British
Standards
institution
CEE
internationat
Commission
on
Rules
for
the
Approval
of
Electrical
Equipment
IEC
International
Electrotechnical
Commission
NEMA
--
National
Electrical
Manufacturer's
Association
SEV
Schweizevischer
Elektrotechischer
Verein
ANS!
C73.20
NEMA
6-15-P
IEC
83
(2931-21)6083-35
Figure
2-1.
Optional
power
cords.
2-1