Controls,
Connectors,
and
Indicators-—
2246
Operators
Tektronix
2246
6083-06
Figure
3-4.
Horizontal
Controls
and
Indicators.
connector
and/or
ADD
may
be
selected
to
supply
the
vertical
(Y-Axis).
The
X-Y
displays
are
horizontally
positioned
by
the
Horizontal
POSITION
control
and
vertically
positioned
by
the
associated
vertical
channel
POSITION
control.
A
AND
B
SEC/DIV
Switch—-Selects
the
horizontal
deflection
rate
(sweep
speed)
for
both
the
A
Sweep
and
the
B
Sweep
in
a
1-2-5
sequence.
Calibrated
sweep
speeds
are
obtained
with
the
A
and
B
SEC/DIV
VAR
control
in
the
calibrated
detent
(fully
clockwise)
position.
A
SEC/DIV-—The
calibrated
A
Sweep
speed
is
selected
only
in
A
Horizontal
MODE
from
0.5
s
per
division
to
20
ns
per
division
(X10
MAG
off).
B
SEC/DIV-—The
calibrated
B
Sweep
speed
is
selected
either
in
ALT
or
B
Horizontal
MODE
from
5
ms
per
division
to
20
ns
per
division
(X10
MAG
off).
A
and
B
SEC/DIV
VAR
Control—Provides
continu-
ously
variable,
uncalibrated
A
Sweep
and
B
Sweep
speeds
to
at
least
2.5
times
slower
than
the
cali-
brated
SEC/DIV
setting.
The
VAR
control
extends
the
slowest
A
Sweep
speed
to
at
least
1.25
sec
per
division.
A
greater-
than
sign
(>)
will
appear
before
each
displayed
SEC/DIV
setting
when
the
VAR
control
is
out
of
its
detent
position.
CURSORS/TIME
POSITION
I+
OR
DELAY
Controi--Positions
both
the
reference
cursor
and
the
delta
cursor
together
when
one
of
the
cursor
measurement
modes
is
selected
{volts
or
time
in
the
A
Horizontal
MODE);
positions
the
reference
delay
and
the
deita
delay
together
when
in
ALT
or
B
Hor-
izontal
MODE
with
ATIME
measurements
active.
The
control
sets
the
B
Sweep
delay
time
in
ALT
or
B
Horizontal
Mode
in
DELAY
measurement
mode
and
positions
the
intensified
zone
for
GATED
CH1/CH2
VOLTMETER
measurements.
CURSORS/TIME
POSITION
-!
OR
A
Control-—
Positions
the
delta
cursor
when
one
of
the
cursor
measurement
modes
is
selected;
sets
the
B
Sweep
delta
delay
in
ALT
or
B
Horizontal
Mode
when
the
REV
APR
1987
oy
RT
est
|
l
|
|
|
l
|
|
|
|
|

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix 2246 and is the answer not in the manual?

Tektronix 2246 Specifications

General IconGeneral
BrandTektronix
Model2246
CategoryTest Equipment
LanguageEnglish

Related product manuals