EasyManuals Logo
Home>Tektronix>Measuring Instruments>492

Tektronix 492 Operator's Handbook

Tektronix 492
42 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #14 background imageLoading...
Page #14 background image
POWER
SOURCE
AND
POWER
REQUIREMENTS
The
492
is
designed
to
operate
from
a
single
-
phase
power
source
that
has
one
of
its
current
-
carrying
conduc
tors
(
neutral
)
at
ground
(
earth
)
potential
.
Operating
from
power
sources
where
both
current
-
carrying
conductors
are
isolated
or
above
ground
potential
(
such
as
phase
-
to
phase
on
a
multi
-
phase
system
or
across
the
legs
of
a
110
220
volt
single
-
phase
,
three
-
wire
system
)
is
not
recommended
,
since
only
the
line
conductor
has
over
current
(
fuse
)
protection
within
the
unit
.
Refer
to
the
Safety
Summary
at
the
front
of
this
manual
.
The
ac
power
connector
is
a
three
-
wire
polarized
plug
with
the
ground
(
earth
)
lead
connected
directly
to
the
instrument
frame
to
provide
electrical
shock
protection
.
If
the
unit
is
connected
to
any
other
power
source
,
the
unit
frame
must
be
connected
to
an
earth
ground
.
Power
and
voltage
requirements
are
printed
on
a
back
panel
plate
mounted
below
the
power
input
jack
.
The
492
can
be
operated
from
either
a
115
Vac
or
230
Vac
nominal
line
voltage
with
a
range
of
90
to
132
or
180
to
250
Vac
,
at
48
to
440
Hz
.
A
multipin
(
harmonica
)
type
connector
on
2-2
the
power
supply
etched
circuit
board
can
be
positioned
to
accommodate
either
voltage
range
.
When
the
power
supply
circuitry
is
changed
to
accommodate
a
different
power
source
,
the
information
plate
on
the
back
panel
must
also
be
changed
to
reflect
the
new
power
re
quirements
.
Refer
power
input
changes
to
qualified
service
personnel
.
Instructions
are
contained
in
the
Service
Information
section
.
WARNING
Only
qualified
service
personnel
should
attempt
to
change
the
power
input
requirements
.
Unfamiliarity
with
safety
procedures
can
result
in
personal
injury
.
Refer
to
the
Safety
Summary
at
the
front
of
this
manual
.
CONTROLS
,
INDICATORS
,
AND
CONNECTORS
The
following
describes
the
function
of
the
controls
,
indicators
,
and
connectors
on
the
front
and
rear
panels
of
the
492.
Figures
2-1
and
2-2
illustrate
their
locations
.
All
options
are
covered
in
this
description
and
some
functions
are
described
in
greater
depth
under
Operating
Informa
tion
.
492
Operator's
Handbook
(
8
)

Other manuals for Tektronix 492

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix 492 and is the answer not in the manual?

Tektronix 492 Specifications

General IconGeneral
BrandTektronix
Model492
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals