Commands Listed in Alphabetical Order
CURSor limits m
easurements to the portion of the waveform between the vertical
bar cursors, even if they are off screen.
Examples
MEASUREMENT:GATING CURSOR turns on measurement gating using the cursors
as limits.
MEASUREMENT:GATING? might return :MEASUR EMENT:GATING CURSOR
indicating that measurements are limited to the portion of the waveform between
the vertical bar cursors.
MEASUrement:IMMed? (Query Only)
Returns all immediate measurement setup parameters.
Group
Measurement
Syntax
MEASUrement:IMMed?
Examples
MEASUREMENT:IMMED? might return
:MEASUREMENT:IMMED:DELAY:D IRECTION FORWARDS;EDGE1 RISE;EDGE2
RISE;:MEASUREMENT:IMMED:TY PE PERIOD;UNITS "s";SOURCE1
CH1;SOURCE2 CH2
MEASUrement:IMMed:DELay? (Query Only)
Returns information about the immediate delay measurement. This c ommand is
equivalent to viewing the delay measurement settings on the measurement readout.
Group
Measurement
Syntax
MEASUrement:IMMed:DELay?
Examples
MEASUREMENT:IMMED:DELAY? might return
:MEASUREMENT:IMMED:DELAY:D IRECTION FORWARDS; EDGE1
RISE;EDGE2 RISE
MSO2000B, DPO2000B, MSO2000 and DPO2000 Series Oscilloscopes Programmer Manual 2-187

Other manuals for Tektronix DPO2012B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix DPO2012B and is the answer not in the manual?

Tektronix DPO2012B Specifications

General IconGeneral
BrandTektronix
ModelDPO2012B
CategoryTest Equipment
LanguageEnglish

Related product manuals