Command Syntax
Table 2-11: Quo
ted String Argument
Symbol Meaning
<QString> Quoted string of AS CII text
A quoted string can include any character dened in the 7-bit ASCII character
set. Follow these rules when you use quoted strings:
1. Use the same type of quote character to open and close the string. For
example:
"this is a valid string".
2. You can mix quotation marks within a string as long as y ou follow the
previous rule. For example:
"this is an 'acceptable' str ing".
3. You can include a quote character within a string by repeating the quote. For
example:
"here is a "" mark".
4. Strings can have upper or lower case characters.
5. If you use a GPIB network, you cannot terminate a quoted string with the
END message before the closing delimiter.
6. A carriage return or line feed embedded in a quoted string does not terminate
the string. The return is treated as another character in the string.
7. The maximum length of a quoted string returned from a query is 1000
characters.
Here are some invalid strings:
"Invalid string argum ent' (quotes are not of the same type)
"te
st<EOI>"
(termination character is embedded in the string)
Block
Several oscilloscope commands use a block argument form, as dened in the
table below.
T
able 2-12: Block Argument
Symbol Meaning
<
NZDig>
A nonzero digit character in the range of 1–9
<Dig>
A digit character, in the r ange of 0–9
<DChar> A character with the hexadecimal equivalent of 00 through FF (0
through 255 decimal)
<Block>
A block of data bytes dened as: <Block> ::=
{#<NZDig><Dig>[<Dig>...][<DChar>...] |#0[<DChar>...]<terminator>}
<NZDig> species the number of <Dig> elements that follow. Taken together,
the <NZDig> and <Dig> elements form a decimal integer that species how
many <DChar> elements follow.
2-8 MSO2000B, DPO2000B, MSO2000 and DPO2000 Series Oscilloscopes Programmer Manual

Other manuals for Tektronix DPO2012B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix DPO2012B and is the answer not in the manual?

Tektronix DPO2012B Specifications

General IconGeneral
BrandTektronix
ModelDPO2012B
CategoryTest Equipment
LanguageEnglish

Related product manuals