Pinpoint trigge
rs
Triggering with B-Event Scan
Use A->B Sequence B-Event Scan to create overlapped eye diagrams synchronized or initiated by an A trigger event.
B-Event Scan is not available on MS O5000B and DP O5000B instruments.
Trig on nth Event captures the nth B-Event that occurs after the A-E vent for all acquisitions. B-Event Scan automatically
advances the B-Event value to capture different portions of the signal.
1. Set the A trigger type and source in the
A Event tab.
2. Set the B trigger type and source in the
B Event tab.
3. To more accurately place the trigger
on the display, check Enhanced
Trigge
ring. To more accurately place
the trigger on noisy signals, also check
Optimized for No isy Signals.
78 MSO/DPO70000DX, MSO/DPO70000C, DPO7000C, and MSO/DPO 5000B Series U ser M anual