Command Groups
Table 2-26: Measurement Commands (cont.)
Command
Description
MEASUrement:MEAS<x>:MEAN?
Returns the mean value accumulated sinc e
the last statistical reset
MEASUrement:MEAS<x>:MINImum? Returns the minimum value found since the
last statistical reset
MEASUrement:MEAS<x>:SOURCE[1] Sets or returns the channel from which
measurements are taken
MEASUrement:MEAS<x>:SOURCE2 Sets or returns the channel to which
measurements are sent
MEASUrement:MEAS<x>:STATE Sets or returns whether the specied
measurement slot is computed and
displayed
MEASUrement:MEAS<x>:STDdev? Returns the standard deviation of values
accumulated since the last statistical reset
MEASUrement:MEAS<x>:TYPe Sets or returns the measurement<x> type
MEASUrement:MEAS<x>:UNIts?
Returns measurement<x> units
MEASUrement:MEAS<x>:VALue? Returns the value of m easurement<x>
MEASUrement:METHod Sets or returns the method used for
calculating reference levels
MEASUrement:REFLevel? Returns the current reference level
parameters
MEASUrement:REFLevel:ABSolute:HIGH Sets or returns the top reference level for
rise time
MEASUrement:REFLevel:ABSolute:LOW Sets or returns the low reference level for
rise time
MEASUrement:REFLevel:ABSolute:MID Sets or returns the mid reference level for
measurements
MEASUrement:REFLevel:ABSolute:MID2 Sets or returns the mid reference level for
delay "to" measurements
MEASUrement:REFLevel:METHod Sets or returns the method for assigning high
and low reference levels
MEASUrement:REFLevel:PERCent:HIGH Sets or returns the top reference percent
level for rise tim e
MEASUrement:REFLevel:PERCent:LOW Sets or returns the low reference percent
level for rise tim e
MEASUrement:REFLevel:PERCent:MID Sets or r eturns the mid reference percent
level for waveform measurements
MEASUrement:REFLevel:PERCent:MID2 Sets or returns the mid reference percent
level for second waveform measurements
MEASUrement:SNAPShot
Displays the measurement snapshot list
MEASUrement:IMMed:S OU rce<x> Sets or returns the source for the current
single channel measurement
2-28 MSO2000B, DPO2000B, MSO2000 and DPO2000 Series Oscilloscopes Programmer Manual

Other manuals for Tektronix MSO2024B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix MSO2024B and is the answer not in the manual?

Tektronix MSO2024B Specifications

General IconGeneral
BrandTektronix
ModelMSO2024B
CategoryTest Equipment
LanguageEnglish

Related product manuals