Table 4: Trigger specifications (cont.)
USB Data Rates Supported: HS: 480 Mbps, Full: 12 Mbps, Low: 1.5 Mbps
Trigger On: Sync, Reset, Suspend, Resume, End of Packet, Token (Address) Packet, Data
Packet, Handshake Packe t, Special Packet, Error
NOTE. HIGH SPEED support available only on M SO4104B, DPO4104B, MSO4104B-L,
DPO4104B-L, MSO4102B-L, DPO4102B-L, MSO 4102B, and DPO4102B models.
Ethernet
Bit Rate: 10BASE-T, 10 Mbps; 100BASE-TX, 100 Mbps
Trigger On: S tart Frame Delimiter (SFD), MAC Address, MAC Length/Type, IP Header, TCP
Header, TCP/IPv4/MAC Client Data, End of Packet, Idle, FCS (CRC) Error, MAC Q-Tag
control Information.
Digital Acquisition Specifications, M SO4000B Series
The following table shows the digital acquisition specifications for the MSO4000B
Series oscilloscopes.
Table 5: Digital acquisition specifications, MSO4000B Series
Characteristic Description
Threshold voltage range -40 V to +40 V
Digital channel timing resolution
2 ns main memory, 60.6 ps for MagniVu memory
Logi
c threshold accuracy
±(100 mV + 3% of threshold setting after c alibration)
Requires valid SPC, as described in step 2 of the Self Test. (See page 55, Self Test.)
Minimum detect able pulse width,
typical
1ns
Using M agniVu memory. Requires the use of 342-1140-00 ground clip on each channel.
18 MSO4000B and DPO4000B Series Specifications and Performance Verification